Since I got so many great responses with my first question I decide to throw another one your way.
I'm trying to properly ground my roof mounted antenna. I have come up with the following two options: 1.) Run #10 thhn stranded wire from the antenna mast to the coax grounding block at the point of entry. Run #10 thhn stranded wire from the coax grounding block to a driven 4 ft copper ground rod. Run #6 thhn stranded wire from the 4 ft copper ground rod to the system ground. 2.) Run #10 thhn stranded wire from the antenna mast to the 2" rigid riser. Run #10 thhn stranded wire from the coax grounding block to a driven 4 ft copper ground rod. Run #6 thhn stranded wire from the 4 ft copper ground rod to the system ground. Similar to the picture below except I will be making the connection to the rigid riser above the roof jack. ![]() Option 2 is preferred because I wont have to run the #10 thhn stranded wire along the roof, around the awning, and down the brick wall to connect to the grounding block. Thoughts?
__________________
"Why don't you put them in your secret compartment" - 12stones (Ricky) |
![]() |
![]() |
![]() |
#2 | |
Black Ops - S.O.B.
![]() Join Date: Oct 2008
First Name: Dave
Location: Side Porta!! Kingsville, Ont., Canada
Posts: 4,222
Trading: (22)
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
![]() Quote:
fyi - http://members.cox.net/pc-usa/station/ground3.htm