Default Hygrometer Calibration Wierdness

OK here is the situation:

I have 3 hygrometers:

#1 is a digital that I have checked with the salt test and it came out at 75% dead nuts. When I put this hygrometer in my humidor with 65% HF beads it reads right on at 65%.

#'s 2 and 3 are HydroSet II digital hygrometers which I recently bought. I salt tested both of them over the course of the past few days and have gotten them dialed in to 75% using the same salt test as I did #1. I am using this setup to do the test, a small glass dish with a clip-on lid that is airtight:


However, after calibrating them to 75% with the salt test, when I put either or both of the two new HydroSet hygrometers into the humidor right next to the one that I know is correctly calibrated, they both read 5 to 7 points lower than # 1. If I put any of them back into the salt test dish and wait, they all come right up to 75%.

Any ideas as to what may be going on here?
TomF is offline   Reply With Quote
Old 03-28-2015, 04:42 PM   #2
The Poet
Il megglior fabbro
 
The Poet's Avatar
 
Join Date: Jun 2009
First Name: Thomas
Location: Hickory, NC
Posts: 8,420
Trading: (2)
The Poet has much to be proud ofThe Poet has much to be proud ofThe Poet has much to be proud ofThe Poet has much to be proud ofThe Poet has much to be proud ofThe Poet has much to be proud ofThe Poet has much to be proud ofThe Poet has much to be proud ofThe Poet has much to be proud ofThe Poet has much to be proud of
Default Re: Hygrometer Calibration Wierdness

Any sufficiently advanced technology is indistinguishable from magic.

Oh, wait . . . maybe Clarke's Third Law doesn't work here. So what about his Second?

The only way of discovering the limits of the possible is to venture a little way past them into the impossible.


Hope that helps.
__________________
Ninety percent of everything is crap - Theodore Sturgeon.
The Poet is offline   Reply With Quote
Old 03-28-2015, 04:51 PM   #3
TomF
Just in from the Storm
 
Join Date: Mar 2015
First Name: Tom
Location: New York
Posts: 28
Trading: (1)
LGC
TomF is on a distinguished road
Default Re: Hygrometer Calibration Wierdness

I'm only tellin' ya...
TomF is offline   Reply With Quote
Old 03-28-2015, 04:57 PM   #4
TomF
Just in from the Storm
 
Join Date: Mar 2015
First Name: Tom
Location: New York
Posts: 28
Trading: (1)
LGC
TomF is on a distinguished road
Default Re: Hygrometer Calibration Wierdness

I'm thinking I should just calibrate them to 65% in the humidor and be done with it.
TomF is offline   Reply With Quote
Old 03-28-2015, 05:16 PM   #5
Wharf Rat
I'll get up and fly away
 
Wharf Rat's Avatar
3
 
Join Date: Oct 2008
First Name: Bob
Location: Florence, SC
Posts: 778
Trading: (7)
RA
Wharf Rat will become famous soon enoughWharf Rat will become famous soon enough
Default Re: Hygrometer Calibration Wierdness

I'd suggest putting all 3 into your salt test setup at the same time.
Wharf Rat is offline   Reply With Quote
Old 03-28-2015, 05:51 PM   #6
TomF
Just in from the Storm
 
Join Date: Mar 2015
First Name: Tom
Location: New York
Posts: 28
Trading: (1)
LGC
TomF is on a distinguished road
Default Re: Hygrometer Calibration Wierdness

Not sure they will all fit, but I will try that. Maybe use a bigger dish.
TomF is offline   Reply With Quote
Old 03-28-2015, 06:41 PM   #7
T.G
Grrrrrr
 
T.G's Avatar
16
 
Join Date: Mar 2009
First Name: The Other Adam
Posts: 15,535
Trading: (37)
Navy (Served With Honor)
T.G has disabled reputation
Default Re: Hygrometer Calibration Wierdness

The salt test has the potential to be very inaccurate depending on how much water is used and unfortunately, it doesn't take much to skew it one way or the other. I would recommend the boveda calibration kit before guessing over setting the hygometers to match one of unkown accuracy
T.G is offline   Reply With Quote
Old 03-28-2015, 06:55 PM   #8
Wharf Rat
I'll get up and fly away
 
Wharf Rat's Avatar
3
 
Join Date: Oct 2008
First Name: Bob
Location: Florence, SC
Posts: 778
Trading: (7)
RA
Wharf Rat will become famous soon enoughWharf Rat will become famous soon enough
Default Re: Hygrometer Calibration Wierdness

Quote:
Originally Posted by TomF View Post
Not sure they will all fit, but I will try that. Maybe use a bigger dish.
I like to do calibration in a heavy ziplock bag. If the hygrometer is adjustable with a knob, you can turn it without opening the bag up.
Wharf Rat is offline   Reply With Quote
Old 03-30-2015, 06:45 AM   #9
TomF
Just in from the Storm
 
Join Date: Mar 2015
First Name: Tom
Location: New York
Posts: 28
Trading: (1)
LGC
TomF is on a distinguished road
Default Re: Hygrometer Calibration Wierdness

Thanks to all for your advice. I got it worked out. The first one turned out to be off.

We can do anything. The impossible just takes longer...
TomF is offline   Reply With Quote
Reply

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT -6. The time now is 05:11 AM.


Powered by vBulletin® Version 3.7.4
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
All content is copyrighted jointly by Cigar Asylum and the content provider.