Part 2 - Day One
No power to unit, no fans inside
The desired outcome for day one was to demonstrate the stability of the unit in a relatively cool environment. The unit was in a room where the temperature only fluctuated between 65 and 71 degrees. During this test the vino was never opened and the unit was unplugged with no circulation. As you can see, there was some fluctuation of the RH. As the temperature rose in the middle of the day, the RH inside the unit fell. After 2pm the top saw the most rapid change while the middle, the bottom and inside the box saw a much slower change. The interesting part was after midnight as the temperature fell, the RH rose again. Notice the change in the middle and inside the box, the middle stayed the same and inside the box dropped another 1% while the top and bottom rose 2%.
Here are the results:
And a few shots of the test throughout the day:
I repeated this test on day two with almost identical results.
Up next; I placed an Oust fan in the unit.